Best Industrial Ceiling Fans For Sale

Best HVLS Commerical Ceiling Fans

  1. Extra large commercial ceiling fans unit of measurement designed to be used in sqmeasures that need totally fully completely different specifications from those fixtures that unit of measurement commonly used for many homes or offices. this might be as well true for warehouses, factories, and classy technical and mechanical buildings, despite the actual fact that people would possibly associate these with the house. business vogue overhead fans unit of measurement those fixtures designed specifically for large-scale cooling and circulation for company buildings.
  2. Temperature and air quality will quickly shift once space fills with individuals. it’s powerful to flow into hot or cold air equally throughout a building. Uneven air will end up hot and cold spots. RTFANS commercial ceiling fans unit of measurement an honest climate management resolution for public areas and industrial warehouses as a result of they homogenize the air and abate on cooling price.
  3. No matter what style of house you wish to maneuver air, RTFANS has the best resolution for creating the occupants softer. With the good solutions for all of your business fan wants — in offices, restaurants, churches and many of. Sector ceiling fans keep even the foremost important, most packed venues comfy and funky whereas saving energy. Their quiet operation makes these fans a perfect resolution for these sorts of areas.

HVLS Fan Specification

Applicable

Applicable for Commercial Area
8ft, 10ft,12ft Diameter HVLS Fans

Model Fan Dia.
(M/FT)
Motor Power
(W)
RPM Air Flow
(m³/min)
Voltage
(V)
Applicable Area
(SQM.)
Noise
(DB)
RTF-SF-4E 4.2m/12ft 800 0~70 8000 24/48 800 42
RTF-SF-3E 3.6m/10ft 680 0~80 6000 24/48 720 40
RTF-SF-2E 2.4m/8ft 680 0~80 4500 24/48 660 40
Model RTF-SF-4E RTF-SF-3E
Fan Dia.(M/FT) 4.2m/12ft 3.6m/10ft
Motor Power(W) 800 680
RPM 0~70 0~80
Air Flow 8000 6000
Voltage(V) 24/48 24/48
Applicable Area 800 720
Noise(DB) 42 40

Features

  1. German “Nord” customized coaxial bevel reduction gears with a diameter of axle 40mm.
  2. German “Simrit” double oil seal design, durable and reliable.
  3. “Shell” top class “Omala” S4 lubrication oil, zero maintenance for over 20000 hours.
  4. low maintenance and long service life.
  5. High efficiency for low operating costs.
  6. Robust grey cast iron housing.
  7. High axial and radial load capacities enable reliable operation.
  8. Quiet running.

  1. High strength aircraft aluminum alloy: AA6063T6511 with PVFD surface coating.
  2. The design developed by Profili 2.0 – professional software for wing airfoils managing, drawing and analysis.
  3. Patented airfoil design, specially designed reinforcing rib support system to increase both strength and flexibility.
  4. Inner equipped steel cable, the stiffened reinforcement combination, the module to prevent fan blade cracking(Optional).
  5. 6 blades, Customized fan blade colour.

  1. Denmark “DANFOSS” frequency converter & German “Schneider” electrical sets.
  2. Penetration of dust is minimized thanks to coated PCBs, the drive ensures reliable and cost-effective operation also in demanding environments.
  3. Radio disturbance from motor cables is limited due to built-in RFI filters.
  4. Lifetime of the drive is extended and reliability improved as a result of the effective heat sink that removes heat from the electronics.
  5. Energy consumption can be reduced as kinetic energy in the application can be transformed into braking power to slow down the motor.

  1. German “Nord” customized coaxial bevel reduction gears with a diameter of axle 40mm.
  2. Innovative double chassis design, more durable and steady.
  3. Imported NASA-inspired super alloy (AA7075).
  4. Precision high-pressure forging japan technology (Σ B 600Mpa).
  5. T6 heat processing.

Unique Cardan joint design, working as a human beings’ joint, to decrease the vibration and keep fan best balanced during operation.

HVLS Fans Wind Chill Effect

The gentle breeze brings by RTFANS HVLS fans to our body can accelerate sweat evaporation and make people feeling cool, usually, this sensible temperature created by wind chill effect can be 5-8℃, in addition, the gentle wind from all sides will make people more comfortable compared with a traditional powerful fan.

How to make people feel cooling down 5-8℃ by use high-volume low-speed fans?

The running of a big diameter industrial fan blade accelerates the airflow and increases the evaporative efficiency of the sweat on a human being’s body, and this evaporation process takes away heat in the body, that’s called wind chill effect.

As for the specific influence created by different wind speeds, please see the above graph, which can show you different temperatures with different wind speeds to make the difference that people feeling.

Application Solutions

HVLS Fans For Warehouse

Whether your business is manufacturing, distribution, storage, processing, repair or packaging, RTFANS improve work efficiency and workplace safety by keeping employees cool and comfortable with affordable cost and less energy consumption.

HVLS Fans For Dining Room

One of the simplest ways to retain diners is to ensure they're comfortable in your restaurant. RTFANS gently and silently move air throughout dining rooms, regulating temperatures.

HVLS Fans For Factory

RTFANS greets guests with gentle breezes. Whether you need airflow in hotel lobbies, ballrooms, gym, suites, corridor or bars, RTFANS deliver.

HVLS Fans Dehumidification

RTFANS HVLS industrial ceiling fan facilitates the flow of air and dispenses the damp, to improve the comfort level for people in the house.

HVLS fan can accelerate the air mixing of whole space which helps to distribute and absorb the odors, smoke, and humidity very well, thus to improve the quality of air and provide a fresh, arid and safe environment.

RH(%)
Inside Air Normal 30% 40% 50% 60% 70% 80%
Inside Air With HVLS Fan 27% 35% 43% 50% 58% 65%
Dehumidification 3% 5% 7% 10% 12% 15%
Reduction Rate 10.00% 12.50% 14.00% 16.67% 17.14% 18.75%

HVLS Fan Space Ventilation

Usually the ventilation is restricted in a tall and large space, and the exhaust fan can barely work for the floor or corner of building where people and equipment located, while HVLS industrial fan can solve these problems completely by sending a well-aligned wind in full space, coordinated with the evaporative air cooler, to improve the air quality and achieve a healthy and comfortable working environment.

 
 

Compared With Powerful Fan

  • Cover 1800m² per unit with 13200m³/min, full space covered with its 7.3m diameter fan blade.
  • Installation by mounted to the ceiling, simple and elegant.
  • Tridimensional and natural breeze from all direction, with most comfortable wind speed 1-3m/s, with less noise.
  • Almost zero maintenance
    after proper installation.
  • 8-10 years.
  • Wind can only reach the area in front of the fan, can not work well if people frequently move.
  • Mounted on the wall or standing on the floor, need space to put or store.
  • Long-time exposure to high-speed wind will cause dizziness,
    noisy during operation.
  • High failure rate, and need maintenance and cleaning frequently.
  • 3-5 years.

Compared With Powerful Fan​

HVLS Fan Powerful Fan
Fan Diameter (m) 7.3 0.75
Power (kW) 1.5 0.36
Air Flow (m³/min) 13,500
(810,000)
300
(18,000)
Effective Area (m²) 1,500 30
Factory Area 9000m² 9000m²
Total Units installed 6 300
Total Kw Installed 9 108
Consumption/Year
@10hrs/day @26 d/m
28,080 336,960

Compared With Powerful Fan

  • During Spring or Autumn when temperature keep in a range from 20-34 ℃, for those space with AC system, it’s awkward to decide if need to run the AC system, while with HVLS fan, you can forget the electricity bill caused by AC system!

  • It cost a huge when AC system fully running, while the HVLS fan can spread the cold air into every corner of the space during AC running, make it more well proportioned.

  • In addition, testing shows that we can save power consumption 20% by setting AC temperature 1℃ higher, HVLS fan can shorten the running time of AC or decrease the running quantity of AC, but achieve a same cooling effect!